Home

  Imprint   Disclaimer

IBHsoftec GmbH

Turmstr. 77

64743 Beerfelden

Tel:     +49 6068 3001

Fax:    +49 6068 3074

info@ibhsoftec.de

Deutsch

Product Selection: S5/S7 SoftPLC

 

SoftPLC S7-315® / S7-416®

The SoftPLC S7-315® / S7-416® executes a program in the same manner as a hardware PLC. The advantage of executing a PLC program this way is, that the PLC status can be displayed in real time without any recompile activities. Since the Soft PLC behaves like a original SIMATIC® PLC, the programming tools S7 for Windows® and STEP®7 can be used. Online connections can be established serial, via Ethernet, via PROFIBUS DP and directly on the same PC. Even for project engineering and diagnostics of the PROFIBUS DP S7 for Windows® or the original STEP®7 tool can be used. The program of a S7-PLC or a Siemens Win AC® SoftPLC including PROFIBUS DP configuration can be transferred to the SoftPLC S7-315® / S7-416®.
Demo Version>

Details>

   

SoftPLC S5-943 / S5-945

The SoftPLC S5-943 / S5-945 executes a program in the same manner as a hardware PLC. The advantage of executing a PLC program this way is, that the PLC status can be displayed in real time without any recompile activities. Since the SoftPLC behaves like a original SIMATIC® PLC, the programming tools S5 for Windows® and STEP®5 can be used. Online connections can be estasblished serial, via Ethernet and directly in the same PC. The program of a S5-PLC can be transferred to the SoftPLC S5-943 / S5-945.

Demo Version>

Details>

   

Timetable:

  Windows NT 4.x/2000/XP/Vista

Compatible to STEP®5

Compatible to STEP®7

SoftPLC S5-943

SoftPLC S5-945

SoftPLC S7-315®

SoftPLC S7-416®

Load Memory

-----

-----

256 kByte

adjustable

Work Memory

48 kByte

720 kByte

256 kByte

adjustable

Memory bit

F 0.0 - 255.7

F 0.0 - 255.7

M 0.0 - 2047.7

M 0.0 - 16383.7

S-flags

 S 0.0 - 4095.7

S 0.0 - 4095.7

-----

-----

Timer

256

256

256

2048

Counter

256

256

256

2048

Digital I/O

I/O 0.0 - 127.7

 I/O 0.0 - 127.7

I/O 0.0 - 127.7

I/O 0.0 - 4095.7

Analog I/O

256

256

1024

4096

Processing time for 1024 instructions*)

Pentium III 600

190 µs

190 µs

100 µs

100 µs

Pentium IV 1,1 GHz

80 µs

80 µs

50 µs

50 µs

Pentium IV 2,6 GHz

55 µs

55 µs

28 µs

28 µs

*)Time setting 50% PLC Time, 50% Windows-Time, 1024 mixed instructions, (50% binary, 50% digital)

 

 

 